To Order Call: 800-817-3486 or Email: sales@mpimorheat.com or Fill a Contact Form
1 Zone | 2 Zone | |
Max. Amperage | 15 Amps | Total of 20 Amps for system |
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. | |
Mold Interface | Accomplished through 1 single 5 wire cable construction of 2 thermocouple leads, 2 power leads and 1 ground lead per zone. | |
Vital Feature | Anti-Arching Circuitry | |
Construction | Steel frame with handle; air vent on bottom & side for cooling; top & bottom module insertion guides; 4 rubber feet; 3 pin male AC input socket installed on top of main frame; 5 pin female power/thermocouple connector (1Z-FC) with latch installed on top of main frame and 3 prong input power cord plug (1Z-PP without input cord) is supplied. NOTE : If a power/thermocouple cable (PTC-1) is not ordered with main frame, 1 or 2 male cable connector/s (1Z-ME) will be provided. | |
Dimensions & Weight | 9″ (H) x 7″ (W) x 11.5″ (D); Approx. 7 lbs (without modules & cables) | |
Compatibility | Compatible with industry standard control modules and main frames |
Max. Amperage | 15 Amps per zone |
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
Circuit Breaker | 50 Amps, 3 Pole ** |
Vital Feature | Anti-Arching circuitry |
Thermocouple | Type “J” |
Mold Interface | Accomplished through dedicated power cord with ground (PWC-5) and Thermocouple cable (THC-5) |
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-5 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. |
Dimensions & Weight | 9″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 15 lbs (without modules & cables) |
Compatibility | Compatible with industry standard control modules and main frames |
Circuit Breaker | (1) 50 Amps, 3 Pole ** | (1) 70 Amps, 3 Pole ** | (2) 50 Amps, 3 Pole ** |
Single 8 Zone main frame construction | Two 8 Zone Main Frames stacked construction | Two 8 Zone Main Frames stacked construction | |
Max. Amperage | 15 Amps per zone | ||
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. | ||
Vital Feature | Anti-Arching circuitry | ||
Thermocouple | Type “J” | ||
Mold Interface | Accomplished through dedicated power cord with ground (PWC-8) and Thermocouple cable (THC-8) | ||
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-812 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. | ||
Compatibility | Compatible with industry standard control modules and main frames | ||
Dimensions & Weight (without modules & cables) | 9″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 15 lbs | 18″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 32 lbs | 18″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 32 lbs |
Circuit Breaker | (1) 50 Amps, 3 Pole ** | (2) 50 Amps, 3 Pole ** | (3) 50 Amps, 3 Pole ** |
Modular Construction | Single 12 Zone main frame construction | Two 12 Zone Main Frames stacked construction. Rigidly connected & pre-wired. | Three 12 Zone Main Frames stacked construction. Rigidly connected & pre-wired. |
Dimensions & Weight (without modules & cables) | 9″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 20 lbs | 18″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 42 lbs | 27″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 66 lbs |
Max. Amperage | 15 Amps per zone | ||
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. | ||
Vital Feature | Anti-Arching circuitry | ||
Thermocouple | Type “J” | ||
Mold Interface | Accomplished through dedicated power cord with ground | ||
(PWC-12) and Thermocouple cable (THC-12) | |||
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-812 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. | ||
Compatibility | Compatible with industry standard control modules and main frames |
97-170 Brockport Dr. Toronto Ontario, Canada M9W 5C8 Ph. : (416) 675-7329 (800) 817-3486 USA/CAN (800) 880-4531 MEX