To Order Call: 800-817-3486 or Email: sales@mpimorheat.com or Fill a Contact Form
Minimum Bending Radius
Minimum bending radius for all mineral insulated cable heaters is two times the sheath width.
Power Calculation:
The required wattage can be calculated using the following formula:
| Wattage = | (Voltage)2 |
| Cable Length (in feet) × Ohms/foot (from part number tables) |
| Description | Information |
|---|---|
| Material | 304 Stainless Steel |
| Maximum Operating Temperature – C | 650 ºC |
| Maximum Operating Temperature – F | 1200 ºF |
| Maximum Watt Densities | 4.6 W/cm^2 |
| Maximum Watt Densities | 30 W/in^2 |
| Description | Information |
|---|---|
| Material | Alloy 600 |
| Maximum Operating Temperature – C | 650 ºC |
| Maximum Operating Temperature – F | 1200 ºF |
| Maximum Watt Densities | 4.6 W/cm^2 |
| Maximum Watt Densities | 30 W/in^2 |