To Order Call: 800-817-3486 or Email: sales@mpimorheat.com or Fill a Contact Form

Square Cable Heater

Standard Lead Times

INFORMATION

Minimum Bending Radius

Minimum bending radius for all mineral insulated cable heaters is two times the sheath width.

Power Calculation:
The required wattage can be calculated using the following formula:

Wattage =(Voltage)2
Cable Length (in feet) × Ohms/foot (from part number tables)
Specifications
DescriptionInformation
Material304 Stainless Steel
Maximum Operating Temperature – C650 ºC
Maximum Operating Temperature – F1200 ºF
Maximum Watt Densities4.6 W/cm^2
Maximum Watt Densities30 W/in^2
DescriptionInformation
MaterialAlloy 600
Maximum Operating Temperature – C650 ºC
Maximum Operating Temperature – F1200 ºF
Maximum Watt Densities4.6 W/cm^2
Maximum Watt Densities30 W/in^2